0%

    GX-6000 PID Gas Monitor

    Sample Draw with PID, IR, O2, CO, H2S, VOC and Super Toxic Sensor Options

    • 5 Operating modes
    • Smallest 6 gas sample draw
    • 2 Interchangeable smart sensor slots
    • 4 PID options: 10.6 (2 ranges) eV, 10.0 eV, and 11.7 eV lamps
    • PID library of over 600 VOCs — Easily switch target VOC from customizable user list or a recently used list
    • Benzene specific version
    • PPM Leak Check mode
    • LEL sensor protection mode
    • Man-down alarm
    • Panic alarm • Auto display rotation
    • Peak-bar display
    • LED Light source
    • Internal sample pump
    • Light weight, small, rugged IP-67
    • Interchangeable battery packs
    • Operates up to 14 hours
    • Field replaceable sensors, batteries, filters and pump
    • Intrinsically safe ATEX / IECEx / cCSAus

    Description

    The GX-6000 is a game changer. This powerful hand-held instrument is capable of simultaneously monitoring up to 6 gases. In addition to the standard 4 confined space gases which include combustibles, O2, CO, & H2S, the GX-6000 has 2 additional smart channels that accept PID, IR or super toxic sensors. Equipped with a strong internal sample pump, a man-down alarm, a panic alarm, an LED flashlight, and large auto rotating LCD display, the GX-6000 can operate as a single gas PID unit or a multifunctional tool utilizing all 6 channels. The GX-6000 with a PID sensor will come equipped with a library of over 600 VOC gases to choose from as standard. Choosing from the library is easy with a personalized favorites list of 30 commonly used VOC’s as well as a list of 8 of the most recently used VOC’s. A benzene-specific version is available using a pre-filter tube for detecting low levels of benzene. Four PID sensors are available, 10.0 eV, 10.6 eV (low or high range), and 11.7 eV. Any combination of two PID sensors can be installed. GX-6000 PID sensors are also resistant to humidity.

    The GX-6000 has a rugged design built for the nastiest environments. It is equipped with a removable impact-resistant rubber boot and a dust and water resistant enclosure with an IP-67 rating. With 5 bright LED lights on 3 sides of the instrument, alarms are easily seen from a variety of perspectives. With vibration and loud audible alarm, GX-6000 will easily alert users when needed.

    6 Operating Modes

    • Normal Mode
    • Barhole Mode
    • Inert Mode
    • Leak Check
    • Snap Log Mode
    • Benzene Specific

    Applications

    • Confined Space Entry
    • Hazmat Response Teams
    • Arson Investigation
    • Remediation Site
    • Perimeter Monitoring
    • Leak Detection
    • Landfill Monitoring
    • Winery Tank Entry

    Specifications

    Gases & Detectable Ranges

    Gas Measuring Range Reading Increment Alarm Set Points Accuracy (which ever is greater)
    PID Sensors
    10.6 Lamp 600 VOC’s 0 – 50,000 ppb 1 ppb: (< 5000 ppb) 10 ppb: (> 5,000 ppb) A1: 5,000 ppb ± 10% of reading, ± 1 digit
    A2: 10,000 ppb
    0 – 6,000 ppm 0.1 ppm: (< 600 ppm) 1 ppm: (> 600 ppm) A1: 400 ppm
    A2: 1,000 ppm
    10.0 Lamp Benzene Specific 0.1 – 50 ppm 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 50 ppm) No Alarms
    300 VOC’s 0 – 100 ppm 0.01 ppm (0 ~ 10 ppm) 0.1 ppm (10 ~ 100 ppm) A1: 5 ppm A2: 10 ppm
    11.7 Lamp High Voltage Lamp 0 – 1000 ppm 0.1 ppm A1: 400 ppm
    A2: 1,000 ppm
    Galvanic
    Oxygen (O2) 0 – 40.0% Vol. 0.1% Vol. A1: 19.5 Vol. ± 0.5% O2
    A2: 23.5 Vol.
    Electro Chemical
    Carbon Monoxide (CO) 0 – 500 ppm 1 ppm A1: 25 ppm ± 5% of reading or ± 5 ppm
    A2: 50 ppm
    TWA 25 ppm
    STEL 200 ppm
    Hydrogen Sulfide (H2S) 0 – 100.0 ppm 0.5 ppm A1: 5.0 ppm ± 5% of reading or ± 2 ppm
    A2: 30.0 ppm
    TWA 1.0 ppm
    STEL 5.0 ppm
    Toxics (EC Sensors)
    Ammonia (NH3) 0 – 400.0 ppm 0.5 ppm A1: 25 ppm ± 10% of reading or ± 5% of full scale
    A2: 50 ppm
    Chlorine (Cl2) 0 – 10.00 ppm 0.05 ppm A1: 0.5 ppm
    A2: 1.0 ppm
    Hydrogen Cyanide (HCN) 0 – 15.0 ppm 0.1 ppm A1: 5 ppm
    A2: 10 ppm
    Nitrogen Dioxide (NO2) 0 – 20.00 ppm 0.05 ppm A1: 3 ppm
    A2: 6 ppm
    Sulfur Dioxide (SO2) 0 – 99.90 ppm A1: 2 ppm
    A2: 5 ppm
    IR Sensors
    Carbon Dioxide (CO2) 0 – 10,000 ppm 20 ppm A1: 5,000 ppm ± 5% of reading or ± 2% of full scale
    TWA 5,000 ppm
    0 – 10.00% Vol. 0.02% A1: 0.50% Vol
    A2: 3.00% Vol
    STEL 3.00% Vol
    TWA 0.50% Vol
    Methane (CH4) 0 – 100% LEL 0 – 100% Vol. 1% LEL/ 0.5% Vol A1: 10% LEL A2: 50% LEL
    Hydrocarbons 0 – 100% LEL 0 – 30% Vol.
    Catalytic
    Hydrocarbons (CH4, std) 0 – 100% LEL 1% LEL A1: 10%LEL ± 5% of reading or ± 2% LEL
    A2: 50%LEL

    Common Specifications

    Alarm Types Gas alarm Man-down Trouble
    Low and high adjustable 1st – self reset 2nd – latching Low flow Sensor connection Low battery Circuit error Calibration range
    Sample Method Sample draw pump, flow rate 0.45 LPM, 50 foot sample range
    Display Digital LCD, autobacklight, peak bar display, auto display rotation, and customize order of gases
    Audible Alarm 95 dB at 1 ft.
    Languages English, Spanish, French, German, Italian, Japanese, Korean, Portuguese, Russian
    Continuous Operation 14 hours on Lithium-ion battery pack. Complete recharge in 3 hours. 8 hours Alkaline battery pack (3 AA size within each pack)
    Operating Temp. & Humidity -4°F to 122°F (-20°C ~ +50℃), 0- 95% RH non condensing
    Dimensions 2.6” W x 7.8” H x 2” D (H200 x W68 x D52 mm) 14 ounce (400g) (with lithium battery pack)
    Case Material Dust and water resistant with IP-67 approval (exclude sample hose and probe)
    Safety Design / Approvals Explosion proof: IECEx , ATEX , TIIS , cCSAus Explosion class :Ex ia IIC T4 Ga Others: CE Marking
      Standard Features 2 Smart sensors slots auto recognize sensor changes Library of over 600 VOC’s User defined VOC list. Up to 30 frequently used Recent VOC list for last 8 selected gases Pump and circuit status indicators User & station ID selection menu Datalogging (interval, alarm trend, station and user ID) Snap logging – on demand data logging Demand zero / Auto zero BUMP and CAL expiration alarm Flashlight IrDA communication LEL sensor protection mode
    Standard Accessories • Rubber boot • Belt clip • Hand strap • Tapper nozzle• Probe with hydrophobic & dust filter 3’ teflon lined hose • Benzene pre-filter tubes and holder (benzene versions)
    Optional Accessories • SDM-6000 calibration station • Bundles with instrument carrying case and accessories • Flexible probes • Up to 50 foot sample hoses • Filter set • IrDA cable
    Warranty Two years material (including sensors) and workmanship. One year for PID sensor (Two monthsfor 11.7 eV lamp)

    Parts

    GX-6000 Spare Parts callout

    Part Number Description
    07-6035 O-ring, P6 EPDM
    07-6036 Gasket for top cover, EPDM Black
    07-6037 Joint pump EPDM black
    07-6038 Gasket for cover, EPDM black
    07-6039 Joint pressure  sensor, EPDM black
    07-6040 Gasket for sensor cover, EPDM black
    07-6041 Gasket for sensor cap, Fluorine-contained rubber Black
    07-6042 Gasket for BUD-6000, EPDM black
    07-6043 Gasket for pump, EPDM black
    10-1089 Screw, 2 x 4.5 SUS
    10-1093RK Screw SUS304 M2x6
    13-0112RK Hand strap
    13-0123 Belt clip with screws
    17-1031 Taper nozzle, red
    20-0326 Rubber protect cover
    21-1833RK Filter case assembly (GX-2012/6000/RP-2009)
    21-1926, 1 ea 21-1926-01, 5 p LCD protection film 5 pcs/pack
    21-1928 RKI Housing assembly for EX  
    21-1929 Protection case, L-1225L black
    21-1930 Sensor case
    21-1931 Sensor cover assembly
    21-1932 Top case assembly
    21-1933 RKI Body case assembly for EX  
    29-6100 Water immersion sensing seal 1 pack = 10 pcs
    30-0022RK Pump RP-12 (GX-2012/6000/CO-FL1/RP- 2009)
    30-1054RK Vibration motor,  A3BE-MT4
    33-0159RK Teflon filter 1 pack = 10 pcs, PF-060 (GX-2003/2012/6000/RP-6 RP-2009/GP-1000)
    33-0560RK PPB pellet for PIS-001 sensor
    33-0562 HPPM pellet for PIS-002 sensor
    33-1112RK Filter (Metal mesh) 1 pack = 10 pcs (GX-2003/2012/6000/RP-6 RP-2009)
    33-7102RK Charcoal filter CF-1821-2 for CO sensor 1 pack = 5 pcs (GX-2009/2012/6000)
    33-7114RK H2S scrubber filter CF-6264-8 for LEL sensor 1 pack = 5 pcs
    47-4001 Connector with cable, MAIN to SENSOR
    49-1050RK Silver oxide battery, SR616SW
    49-1120 Alkaline  battery (AA size) TOSHIBA
    49-1619 Lithium-ion battery unit BUL-6000
    49-1620 Alkaline  battery unit, BUD-6000
    49-2982-01 Battery charger unit BC-6000 (with AC adaptor)
    51-1139 LCD module BTD-128160B-FBWB-G-G
    51-1501RK PID lamp 10.6eV LA4SM600
    57-1286 Main PCB assembly
    DES-3311-1 DES-3311-1 CO2 0-5vol% Sensor
    DES-3311-2 DES-3311-2 HC 0-100%LEL 0-30vol% Sensor
    ES-1821 CO sensor Sensor
    ES-1827I H2S sensor Sensor
    ESS-03DH-HCN ESS-03DH HCN 0-15ppm Sensor
    ESS-03DH-NO2 ESS-03DH NO2 0-9ppm Sensor
    ESS-03DH-SO2 ESS-03DH SO2 0-6ppm Sensor
    NC-6264A HC sensor Sensor
    OS-BM2 O2 sensor Sensor
    PID-001 PIS-001 Iso-buthylene 0-50000ppb Sensor
    PID-002 PIS-002 Iso-buthylene 0-6000pm Sensor

    Download

    GX-6000 Software


    download

    GX-6000 datalogging program 30.5MB version 06125

    download
    GX-6000 Firmware Update Instructions (step by step procedure)

    download
    TWA Alarm Setting for continuous operation (step by step procedure for turning off TWA Alarms)

    Manuals & Literature

    GX-6000 Datasheet

    GX-6000 Product Datatsheet

    GX-6000 PID Datasheet

    GX-6000 PID Datatsheet

    GX-6000 Datasheet

    GX-6000 Brochure

    GX-2012 Manual

    GX-6000 Operator’s Manual

    GX-2012 Manual

    GX-6000 PID Operator’s Manual

    GX-6000 Datalogging Manual
    GX-6000 Datalogging Manual
    GX-6000 Quick Reference Card
    GX-6000 Quick Reference Card

    Training Video

    This video is also available on YouTube and CD (by request)

    Distributor Resources

    GX-6000 Price List & Resources